7.3 Communication
When communication of either text or commands is interrupted, try the steps below.
First, check the communication cable for continuity. If you don't have an ohm meter, try using a
different communication cable. If you are using a PC try using a different Com Port.
Next, please ensure that the display module is set to communicate on the protocol that you are
using, by checking the Protocol Select Jumpers.
In serial protocol, ensure that the host system and display module are both communicating on
the same baud rate. The display will communicate at either 9600bps or 19200bps only.
Match Rx from the MOS-AL162F to the transmitting pin from your host and the Tx pin to the
receiving pin.
Unlock the display. See the Set and Save Data Lock command for more info.